RF Probe
Model 10 (dc to 11 GHz )
 Model 10 (dc to 11 GHz )
  • Parameter
  • Download

PICOPROBE® MODEL 10 is a multipurpose, high speed, passive probe which can be used for driving as well as receiving signals. The Model 10 consists of a one meter length of flexible 50 ohm coaxial cable terminated by a carefully trimmed SMA on one end and by a miniature, high speed 50 ohm connector, specially developed to receive Model 10 replaceable coaxial probe tips, on the other. The 50 ohm coaxial cable was custom designed for Model 10 to be high speed, yet very flexible, so that moving the cable would not disturb the probe points.

Adaptable for a wide range of applications, the Model 10 uses a variety of special purpose, easily replaceable probe tips. Each probe tip consists of a 1.5 inch long 50 ohm semi-rigid coaxial line, a retaining nut, one or two probe points, and a variety of electrical components tailored to achieve the desired electrical characteristics. To drive or receive signals on 50 ohm circuit points, the Model 10 should be fitted with a probe tip that has two probe points, one for the ground and one for the signal.

Probe points which extend 0.120 inches beyond the 50ohm coaxial probe tip have been designed fordc to 3.5 GHz response and probe points which extend 0.030 inches beyond the probe tip have been designed for dc to 7 GHz response. The longer 0.120 inch tips are more flexible, making them more durable and easier to use than the shorter 0.030 inch style.

To receive signals from high impedance circuit points, Model 10 probe tips with a 250 ohm, 500 ohm, or 5 k ohm input resistance should be used. All have been trimmed to compensate for cable loss and to minimize the need for a short ground. Grounding methods would depend upon the desired frequency response and range from dual probe points to a 6 inch long flexible ground strap. In applications where many circuit points must be accessed and ground is not conveniently located, a flexible ground strap can be substituted for the ground point.

The 250 ohm tip should be used with 0.180 inch long dual probe points to achieve dc to 10 GHz response. The signal will be attenuated by 5:1. The 500 ohm tip should be used either with 0.180 inch long dual probe points to achieve dc to 11 GHz response or with a 2 inch long ground strap to achieve dc to 4 GHz response. The signal will be attenuated by 10:1.

The 5k ohm tip should be used either with 0.180 inch long dual probe points to achieve dc to 5 GHz response, a 2 inch ground strap to achieve dc to 4 GHz response, or a 6 inch ground strap to achieve dc to 2 GHz response. The signal will be attenuated by 100:1.

To drive high impedance circuit points Model 10 probe tips with a 50 ohm terminating resistor should be used.

Model 10 was designed to be attached to any micropositioner for use on any probe station. Simply state the make and model number when ordering and the properly shaped probe will be delivered to you.



MODEL 10 SPECIFICATIONS
50 ohm input impedance mode
Probe Wire Length 0.120 inch 0.030 inch
Frequency Response: dc to 3.5 GHz dc to 7 GHZ
Insertion Loss: 3 dB 3 dB
Return Loss: greater than 10 dB greater than 10 dB
Attenuation: 1:1 1:1



250 ohm input impedance mode
Frequency Response dc to 10 GHz(-3 dB)
Attenuation> 5:1
500 ohm input impedance mode
Frequency Response: dc to 11 GHz(-3 dB)
Attenuation: 10:1


5K ohm input impedance mode
Frequency Response: dc to 5 GHz(-3 dB)
Attenuation: 100:1


Model 10 Replacement Tips
Part Number System
Model
Number
Added Resistance to
50 ohm Coaxial Tip
Outside Diameter of
Probing Wire
Probing Wire
Material
No. of
Probing Wires
Ground
R/L
Space Between
Points
10- 50/30 = no added resistance (50 ohm coax to 0.030" long probe tips) 125=125 micron wire sharpened to approx. 5 microns for tungsten and 25 microns for Pd or BeCu W=Tungsten 1=one signal wire only R=Right
L=Left
Ground on Right or Left side of signal point as seen looking from front to back of Model 10
Spacing between signal and ground points(indicate distance in inches or microns)
10- 50/120 = no added resistance (50 ohm coax to 0.120" long probe tips) 60=60 micron wire sharpened to approx. 3 microns for tungsten and 10 microns for Pd or BeCu Pd=Palladium
Only available in 200 micron diameter with 2.5 micron point radius or 12.5 micron point radius
2=one signal wire and one ground wire
10- 50T = 50 ohm resistor placed between center conductor and shield just before probe tips 35=35 micron wire sharpened to approx. 2 microns(tungsten only) BeCu=Beryllium Copper End Part Number here if "1" is entered
10- 50C =a capacitor placed between center conductor and shield just before probe tips(specify value) 22=22 micron wire sharpened to approx. 1 microns(tungsten only)
10- 250=250 ohm input resistor
attenuates 5:1
10=10 micron wire sharpened to approx. 0.2 microns(tungsten only)
10- 500=500 ohm input resistor
attenuates 10:1
10- 1K=1K ohm input resistor
attenuates 20:1
10- 2.5K=2.5K ohm input resistor
attenuates 50:1
10- 5K=5K ohm input resistor
attenuates 100:1

EXAMPLE:

10-500-60-W-2-R-120 micron – Denotes a Model 10 tip with 500 ohm input resistance, 60 micron probing wires, one signal and one ground wire made of tungsten, the ground is on the right side of the signal wire, and the space between probe points is 120 microns.









Recommended Products
主站蜘蛛池模板: 男插女青青影院 | 男同GV在线观看网站 | 饥渴的熟妇张开腿呻吟视频 | 亚洲精品国产一区二区的区别 | 女人色极品影院 | 91精品视频免费看 | 国产v亚洲v天堂a_亚洲 | 樱花视频在线观看进击的巨人第三季 | av亚洲av影院av天堂 | 四虎在线精品 | 浴室边摸边吃奶边做边爱 | 国产在线视频主播区 | 国产va在线视频 | 国产午夜精品免费一区二区三区视频 | 亚洲AV无码一区二区三区鸳鸯影院 | 东北老女人高潮疯狂过瘾对白 | 99riav国产一区二区三区 | 日韩精品 中文字幕 一区 | 免费毛片av| 性生交裸片免费看 | 毛片女女女女女女女女女 | 国产成人免费观看久久久 | 一级特黄国产高清毛片97看片 | 国产色情理论在线观看视频 | 偷拍盗摄66av99 | 香蕉久久精品日日躁夜夜躁夏 | 男人的天堂v在线播放 | 久久国产精品人妻无码 | 亚洲第一av男人的天堂 | 午夜成人毛片免费观看蜜桔视频 | 色婷婷香蕉在线一区二区 | 欧美高清性色生活片免费观看 | 欧美成人免费一级 | 国产又粗又硬又大爽黄老大爷视频 | 在线观看日批视频 | 国产精品国 | 日本曰又深又爽免费视频 | 久久久欧美日韩精品一区 | 中文字幕无码视频手机免费看 | 男女在一起拔萝卜免费视频大全 | 波多野结衣av在线观看 |