国产日韩欧美中文_久久精品国产亚洲AV久_嫩草嫩草嫩草影院_亚洲Av无码一区二区三区在线观看_90后性爱视频_亚洲乱妇老熟女爽到高潮的片

射頻探針
Model 10 (dc to 11 GHz )
 Model 10 (dc to 11 GHz )
  • 規格參數
  • 資料下載


PICOPROBE® MODEL 10

PICOPROBE® MODEL 10 is a multipurpose, high speed, passive probe which can be used for driving as well as receiving signals. The Model 10 consists of a one meter length of flexible 50 ohm coaxial cable terminated by a carefully trimmed SMA on one end and by a miniature, high speed 50 ohm connector, specially developed to receive Model 10 replaceable coaxial probe tips, on the other. The 50 ohm coaxial cable was custom designed for Model 10 to be high speed, yet very flexible, so that moving the cable would not disturb the probe points.

Adaptable for a wide range of applications, the Model 10 uses a variety of special purpose, easily replaceable probe tips. Each probe tip consists of a 1.5 inch long 50 ohm semi-rigid coaxial line, a retaining nut, one or two probe points, and a variety of electrical components tailored to achieve the desired electrical characteristics. To drive or receive signals on 50 ohm circuit points, the Model 10 should be fitted with a probe tip that has two probe points, one for the ground and one for the signal.

Probe points which extend 0.120 inches beyond the 50ohm coaxial probe tip have been designed fordc to 3.5 GHz response and probe points which extend 0.030 inches beyond the probe tip have been designed for dc to 7 GHz response. The longer 0.120 inch tips are more flexible, making them more durable and easier to use than the shorter 0.030 inch style.

To receive signals from high impedance circuit points, Model 10 probe tips with a 250 ohm, 500 ohm, or 5 k ohm input resistance should be used. All have been trimmed to compensate for cable loss and to minimize the need for a short ground. Grounding methods would depend upon the desired frequency response and range from dual probe points to a 6 inch long flexible ground strap. In applications where many circuit points must be accessed and ground is not conveniently located, a flexible ground strap can be substituted for the ground point.

The 250 ohm tip should be used with 0.180 inch long dual probe points to achieve dc to 10 GHz response. The signal will be attenuated by 5:1. The 500 ohm tip should be used either with 0.180 inch long dual probe points to achieve dc to 11 GHz response or with a 2 inch long ground strap to achieve dc to 4 GHz response. The signal will be attenuated by 10:1.

The 5k ohm tip should be used either with 0.180 inch long dual probe points to achieve dc to 5 GHz response, a 2 inch ground strap to achieve dc to 4 GHz response, or a 6 inch ground strap to achieve dc to 2 GHz response. The signal will be attenuated by 100:1.

To drive high impedance circuit points Model 10 probe tips with a 50 ohm terminating resistor should be used.

Model 10 was designed to be attached to any micropositioner for use on any probe station. Simply state the make and model number when ordering and the properly shaped probe will be delivered to you.



MODEL 10 SPECIFICATIONS
50 ohm input impedance mode
Probe Wire Length 0.120 inch 0.030 inch
Frequency Response: dc to 3.5 GHz dc to 7 GHZ
Insertion Loss: 3 dB 3 dB
Return Loss: greater than 10 dB greater than 10 dB
Attenuation: 1:1 1:1



250 ohm input impedance mode
Frequency Response dc to 10 GHz(-3 dB)
Attenuation> 5:1
500 ohm input impedance mode
Frequency Response: dc to 11 GHz(-3 dB)
Attenuation: 10:1


5K ohm input impedance mode
Frequency Response: dc to 5 GHz(-3 dB)
Attenuation: 100:1

Model 10 Replacement Tips
Part Number System
Model
Number
Added Resistance to
50 ohm Coaxial Tip
Outside Diameter of
Probing Wire
Probing Wire
Material
No. of
Probing Wires
Ground
R/L
Space Between
Points
10- 50/30 = no added resistance (50 ohm coax to 0.030" long probe tips) 125=125 micron wire sharpened to approx. 5 microns for tungsten and 25 microns for Pd or BeCu W=Tungsten 1=one signal wire only R=Right
L=Left
Ground on Right or Left side of signal point as seen looking from front to back of Model 10
Spacing between signal and ground points(indicate distance in inches or microns)
10- 50/120 = no added resistance (50 ohm coax to 0.120" long probe tips) 60=60 micron wire sharpened to approx. 3 microns for tungsten and 10 microns for Pd or BeCu Pd=Palladium
Only available in 200 micron diameter with 2.5 micron point radius or 12.5 micron point radius
2=one signal wire and one ground wire
10- 50T = 50 ohm resistor placed between center conductor and shield just before probe tips 35=35 micron wire sharpened to approx. 2 microns(tungsten only) BeCu=Beryllium Copper End Part Number here if "1" is entered
10- 50C =a capacitor placed between center conductor and shield just before probe tips(specify value) 22=22 micron wire sharpened to approx. 1 microns(tungsten only)
10- 250=250 ohm input resistor
attenuates 5:1
10=10 micron wire sharpened to approx. 0.2 microns(tungsten only)
10- 500=500 ohm input resistor
attenuates 10:1
10- 1K=1K ohm input resistor
attenuates 20:1
10- 2.5K=2.5K ohm input resistor
attenuates 50:1
10- 5K=5K ohm input resistor
attenuates 100:1

EXAMPLE:

10-500-60-W-2-R-120 micron – Denotes a Model 10 tip with 500 ohm input resistance, 60 micron probing wires, one signal and one ground wire made of tungsten, the ground is on the right side of the signal wire, and the space between probe points is 120 microns.









推薦產品
主站蜘蛛池模板: 午夜精品久久久久久久久久久久久久 | 国产V在线在线观看视频 | CHINESESPANK国产免费网站 | 日韩精品免费一区二区 | 国产一级a一级a爰片免费无 | 国产乱人伦偷精精品视频 | 国产免费无码AV在线观看 | FUCK四川老女人HD | 久久久无码精品一区二区三区蜜桃 | 挺进朋友人妻的身体里 | 狠狠色狠狠色综合日日小说 | 亚洲中文字幕无码久久2017 | 国产成年女人免费视频播放a | 亚洲第一区在线 | 3d动漫精品一区二区三区 | 国产精品51麻豆cm传媒 | 91丨九色丨国产 | 99久久99久久免费精品 | 老逼av | 在线观看av网| 18无遮挡啪啪无码网站免费看 | 岛国无码av不卡一区二区 | 综合欧美丁香五月激情 | 国产成人免费看 | 欧美一级爱爱视频 | 天天躁狠狠躁狠狠躁性色AV | 国产精品自产拍高潮在线观看 | 91丨porny在线牛牛影视 | 日本免费无码XXXXX视频 | 女人天堂一区二区三区 | 国产成人久久精品77777 | 国产精品四 | 狠狠干第一页 | 2828无码高潮毛片 | 欧美丰满熟妇乱XXXXX网站 | 欧美孕妇色xxxxx | 国内午夜国产精品小视频 | 欧美草草草 | 成年美女黄网站色奶头大全 | 久精品国产欧美亚洲色aⅴ大片 | 无遮挡又色又刺激的女人视频 |